Novotronic Models
Technical Information
63
6.3.2 Selected Temperature Exceeded
Symptom
The unit heats up to a higher temperature then selected. The selecting
operating mode and temperature registered by the electronic unit and
heating takes place to the desired temperature. If a software fault were to
occur the electronic will increase the temperature until the safety
thermostat activates to cut off the heat. The increased temperature will
be displayed.
Cause
Software fault in the electronic unit EPL 710-712
Parts required
Quantity Material Number Nomenclature
1 04996455 Electronic unit EPL 710
1 05290132 Electronic unit EPL 712
Remedy
Replace applicable electronic and program