(CDN) (USA) Electrical connection
The automatic ignition requires connec- Technical data CDN / USA
tion to an a.c. single phase 120
V,
T
, . .„ ., .
oc
...
„„ ,, , r- Tota connected oad 25 W
60 Hz power supply. Fuse rating is
15 A. Actual power consumption Electrical connection to 3 prong wall
(during ignition only) is 25
W.
outlet:
T
. .. , . . . 120V/60Hz/15A
These appliances are factory equipped
with a power supply cord ready for Plug rating 10 A
connection to an electrically grounded
n
., ..
H
. ,
0 m
. , . . . .. ./
y
i i Power cord length 1.1 m (3 ft)
socket which complies with your local
electrical codes or with the:
National Electical Code ANSI/NFPA
No.
70-1481 for the USA
or
Canadian Electrical Code Part
Canada.
for
Ensure that the reeptacle is so
posi-
tioned that it is easily accessible when
the appliance is built in.
Check that data given on the data plate
under the appliance complies with the
main voltage.
WARNING:
THIS APPLIANCE MUST BE
GROUNDED.
[
Do not cut or remove the grounding
prong from this
plug.
18
AUS
Electrical connection AUS
Electrical connection of the appliance
should be undertaken by a suitably
competent person in strict accordance
with national and local safety regula-
tions.
For extra safety it is advisable to install
a residual current device (RCD), with a
trip current of 30 mA.
The appliances are supplied with a
mains cable for connection to single
phase 240
V,
50 Hz supply. The plug
rating and rated load are given on the
data plate.
Connection should be made by a
switched socket. The On-Off switch
should be easily accessible after the
appliance has been built-in.
Electrical connection NZ
The appliances are supplied with a
mains cable for connection to single
phase 230
V,
50 Hz supply. The plug
rating and rated load are given on the
data plate.
Important:
The wires in the mains lead are
col-
oured in accordance with the following
code:
Green/yellow = earth
Blue = neutral
Brown = live
NZ) Electrical connection
As the colours of the wires in the mains
lead of this appliance may not corre-
spond with the coloured markings ident-
ifying the terminals in your
plug,
pro-
ceed as follows:
The wire which is coloured green and
yellow must be connected to the termi-
nal in the plug which is marked with the
letter
E
or by the earth symbol -i or
col-
oured green or green and yellow.
The wire which is coloured blue must
be connected to the terminal which is
marked with the letter N or coloured
black.
The wire which is coloured brown must
be connected to the terminal which is
marked with the letter A or coloured red.
WARNING
THIS APPLIANCE MUST BE
EARTHED.
Technical data AUS (NZ)
Total connected load 25 W
Electrical connection:
50 Hz, 240 V (230 V)
Plug rating 10 A
Connection cable 1.10 m
If the connection cable needs replac-
ing,
only use cable with at least
3 x
1
mm
2
.
19
Comentarios a estos manuales