All electrical work should be carried out
by a competent person, in strict
accordance with national and local
safety regulations.
For extra safety it is advisable to install
a residual current device (RCD), with a
trip current of 30 mA.
Connection for each appliance should
be made via a suitable isolator.
The data plate gives the necessary
data for connection.
Voltage: 230 - 240 V, 50 Hz
Rated load: see data plate
Plug rating: 10 A
Test marks Gas safety
Electrical safety,
C-Tick Mark.
WARNING
THIS APPLIANCE MUST BE
EARTHED
Important:
The wires in the mains lead are
coloured in accordance with the
following code:
Green/yellow = earth
Blue = neutral
Brown = live
As the colours of the wires in the mains
lead of this appliance may not
correspond with the coloured markings
identifying the terminals in your plug
proceed as follows:
The wire which is coloured green and
yellow must be connected to the
terminal in the plug which is marked
with the letter E or by the earth symbol
z or coloured green or green and
yellow.
The wire which is coloured blue must
be connected to the terminal which is
marked with the letter N or coloured
black.
The wire which is coloured brown must
be connected to the terminal which is
marked with the letter A or coloured
red.
Electrical connection