Miele – Induction cooktops
Model no KM 5947 KM 5948 KM 5945 LPT KM 5955 LPT KM 5975 KM 5993 LPT KM 5997
Design
Narrow, protruding frame
Flush installation*
1
)
Flat, onset frame
Bevelled glass edges
Décor basalt grey
Black ‘Lightprint’ surface graphics
Controls
Sensor touch controls
Power settings 1–9 1–9 1–9 1–9 1–9 1–12 1–12
Lightring indicators
Integrated booster function
TwinBooster 1 1 2 2 1 2 2
Maximum timer programming h 9.5 9.5 9.5 9.5 9.5 9.5 9.5
External appliance dimensions
Width cm 57.4 59.2 61.4 76.4 91.6 93 92.8
Depth cm 50.4 49.2 51.4 50.4 41.6 51.4 51.2
Benchtop cutout dimensions*
2
)
Width cm 56 59.6 60 75 88.6 91.6 93.2
Depth cm 49 49.6 50 49 38.6 50 51.6
Cooking zones/design
No. of cooking zones 3 3 4 4 4 5 5
Front left cm 18–28 18–28 16–23 16–23 16–23 16–23 16–23
Rear left cm 10–16 10–16 10–16 10–16
Centre left cm 10–16
Centre cm 18–28 18–28
Centre right cm 14–20
Front right cm 10–16 10–16 14–20 14–20 14–20 14–20 14–20
Rear right cm 14–20 14–20 14–20 14–20 14–20 14–20
Casserole area cm 20 x 30 20 x 30
Cooking zones/max.output (Booster)
Front left kW 2.4 (3.7) 2.4 (3.7) 2.3 (3.7) 2.3 (3.7) 2.3 (3.7) 2.3 (3.7) 2.3 (3.7)
Rear left kW 1.4 (1.8) 1.4 (1.8) 1.4 (1.8) 1.4 (1.8)
Centre left kW 1.4 (1.8)
Centre kW 2.4 (3.7) 2.4 (3.7)
Centre right kW 1.85 (2.9)
Front right kW 1.4 (1.8) 1.4 (1.8) 1.85 (2.9) 1.85 (2.9) 1.85 (2.9) 1.85 (2.9) 1.85 (2.9)
Rear right kW 1.85 (2.9) 1.85 (2.9) 1.85 (2.9) 1.85 (2.9) 1.85 (2.9) 1.85 (2.9)
Casserole area kW 2.3 (3.7) 2.3 (3.7)
Safety
Pan/pan size sensor
Automatic safety switch-off
Residual heat indicators
Overheating protection
Integrated cooling fan
Fault monitoring
System lock
Electrical connection
Connection cable length m 1.4 1.4 1.4 1.4 1.4 1.4 1.4
Voltage V 230 230 230 230 230 230 230
Connected load kW 7.4 7.4 7.4 7.4 7.4 11.1 11.1
Radio and TV suppression
Mains interference suppressed
Literature supplied
Operating and installation instructions
Notes:
• = yes, – = no
*
1
) Only suitable for installation in granite, marble, tiled or solid wood worktops. Synthetic materials such as Corian or Askilan are not suitable.
*
2
) Nominal recess dimensions, please refer to more comprehensive installation instructions provided with product.
All appliances must be installed by a suitably qualified person in accordance with local and national regulations.